Type II, Flush Trim, 1-1/2"

Type II, Flush Trim, 350, 1-1/2" 

download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png

A - Hinge Jamb

A1 - Hinge Jamb with Setting Channel

B - Strike Jamb

B1 - Strike Jamb with Setting Channel

C - Header

C1 - Header with Setting Channel

D - Sidelite Strike Jamb

E - Glass Transom Header

F - Glass Base (Drywall)

F1 - Glass Base (Floor)

F2 - 4in Glass Base

G - Mid-Height Base

GP1 - 90 Degree Corner with 2 Glass Jambs

GP2 - 90 Degree Corner with 1 Glass Jambs and 1 Door Jamb

GP3 - Angled Corner with 2 Glass Jambs

GP4 - Angled Corner with 1 Glass Jamb and 1 Door Jamb

GP5 - 3-Way Post with 3 Glass Jambs

GP6 - 3-Way Post with 2 Glass Jambs and 1 Door Jamb

GP7 - 3-Way Post with 1 Glass Jamb and 2 Door Jambs

GP8 - 4-Way Post with 4 Glass Jambs

H - Vertical Mullion

I - Vertical Glass Jamb

I1 - Vertical Glass Jamb with Setting Channel

J - Glass Jamb Header

J1 - Glass Jamb Header with Setting Channel

K - Wall End Cap

K1 - Wall End Cap with Setting Channel

L - Wall End Cap Header

L1 - Wall End Cap Header with Setting Channel

M - Wall End Cap with Glazing Pocket

P - 1.5in Trim with Retainer

A - Hinge Jamb

A1 - Hinge Jamb with Setting Channel

B - Strike Jamb

B1 - Strike Jamb with Setting Channel

C - Header

C1 - Header with Setting Channel at Bulkhead

C2 - Header with Setting Channel at Ceiling Grid

D - Sidelite Strike Jamb

D1 - Strike Jamb with Solid Back

E - Glass Transom Header

F - Glass Base (Drywall)

F1 - Glass Base (Floor)

F2 - 4in Glass Base

G - Mid-Height Base

GP1 - 90 Degree Corner with 2 Glass Jambs

GP2 - 90 Degree Corner with 1 Glass Jamb and 1 Door Jamb

GP3 - Angled Corner with 2 Glass Jambs

GP4 - Angled Corner with 1 Glass Jamb and 1 Door Jamb

GP5 - 3-Way Post with 3 Glass Jambs

GP6 - 3-Way Post with 2 Glass Jambs and 1 Door Jamb

GP7 - 3-Way Post with 1 Glass Jamb and 2 Door Jambs

GP8 - 4-Way Post with 4 Glass Jambs

H - Vertical Mullion

I - Vertical Glass Jamb

I1 - Vertical Glass Jamb with Setting Channel

J - Glass Jamb Header

J1 - Glass Jamb Header with Setting Channel

J2 - Glass Jamb Header with Setting Channel at Ceiling Grid

K - Wall End Cap

K1 - Wall End Cap with Setting Channel

L - Wall End Cap Header

L1 - Wall End Cap Header with Setting Channel

M - Wall End Cap with Glazing Pocket

N - Flush Drywall Track

O - Reveal Drywall Track

P - 1.5in Trim with Retainer

Type II, Flush Trim, 462, 1-1/2" 

download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png

A - Hinge Jamb

B - Strike Jamb

C - Header

D - Sidelite Strike Jamb

E - Glass Transom Header

F - Glass Base (Drywall)

F1 - Glass Base (Floor)

F2 - 4in Glass Base

G - Mid-Height Base

H - Vertical Mullion

I - Vertical Glass Jamb

J - Glass Jamb Header

K - Wall End Cap

L - Wall End Cap Header

M - Wall End Cap with Glazing Pocket

P - 1.5in Trim with Retainer

Type II, Flush Trim, 487, 1-1/2" 

download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png

A - Hinge Jamb

A1 - Hinge Jamb with Setting Channel

B - Strike Jamb

B1 - Strike Jamb with Setting Channel

C - Header

C1 - Header with Setting Channel at Bulkhead

C2 - Header with Setting Channel at Ceiling Grid

D - Sidelite Strike Jamb

D1 - Strike Jamb with Solid Back

E - Glass Transom Header

E1  - Glass Transom Cased Opening Header

F - Glass Base (Drywall)

F1 - Glass Base (Floor)

F2 - 4in Glass Base

G - Mid-Height Base

GP1 - 90 Degree Corner with 2 Glass Jambs

GP2 - 90 Degree Corner with 1 Glass Jamb and 1 Door Jamb

GP3 - Angled Corner with 2 Glass Jambs

GP4 - Angled Corner with 1 Glass Jamb and 1 Door Jamb

GP5 - 3-Way Post with 3 Glass Jambs

GP6 - 3-Way Post with 2 Glass Jambs and 1 Door Jamb

H - Vertical Mullion

I - Vertical Glass Jamb

I1 - Vertical Glass Jamb with Setting Channel

J - Glass Jamb Header

J1 - Glass Jamb Header with Setting Channel at Bulkhead

J2 - Glass Jamb Header with Setting Channel at Ceiling Grid

K - Wall End Cap

K1 - Wall End Cap with Setting Channel

L - Wall End Cap Header

L1 - Wall End Cap Header with Setting Channel

M - Wall End Cap with Glazing Pocket

N - Flush Drywall Track

O - Reveal Drywall Track

P - 1.5in Trim with Retainer

Type II, Flush Trim, 612, 1-1/2" 

download.png
download.png
download.png
download.png
download.png

A - Hinge Jamb

B - Strike Jamb

C - Header

K - Wall End Cap

L - Wall End Cap Header

Type II, Flush Trim, 725, 1-1/2" 

download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png
download.png

A - Hinge Jamb

B - Strike Jamb

C - Header

D - Sidelite Strike Jamb

E - Glass Transom Header

F - Glass Base (Drywall)

F1 - Glass Base (Floor)

F2 - 4in Glass Base

G - Mid-Height Base

H - Vertical Mullion

I - Vertical Glass Jamb

J - Glass Jamb Header

K - Wall End Cap

L - Wall End Cap Header

M - Wall End Cap with Glazing Pocket

P - 1.5in Trim with Retainer

  • Facebook Social Icon
  • Twitter Social Icon